fiorini SET PLUS 2.0 - 25 - User Manual

fiorini SET PLUS 2.0 - 25
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MODULO PER LA PREPARAZIONE ISTANTANEA
DI ACQUA CALDA SANITARIA
ON-DEMAND DOMESTIC
HOT WATER PREPARATION UNIT
SET 2.0
SET 2.0
Taglie: 60-70-80-100-120-200
SET PLUS 2.0
Taglie: 25-35-40
Lingua/ Language
IT-EN
Cod. - Part n. 826050753
Rev. - Rev. 5
Data - Date 11/2016
MANUALE D’USO E MANUTENZIONE
USE AND MAINTENANCE MANUAL
Istruzioni originali in lingua italiana - English translation of the original instructions in Italian

Table of Contents

Questions and Answers

  • J
    Jose CookAug 10, 2025
    What to do if safety valves are triggered in fiorini SET PLUS 2.0 - 25 Industrial Equipment?
    • R
      Renee SmithAug 10, 2025
      If the safety valves are triggered in your Fiorini Industrial Equipment, it could be due to the system’s load pressure being too high. In this case, you should release pressure. Alternatively, the expansion tank might not be filled or could be defective, so you should fill or replace the expansion tank.
  • E
    elizabethdavisAug 15, 2025
    How to troubleshoot if the pump does not start in fiorini SET PLUS 2.0 - 25?
    • Z
      zwadeAug 15, 2025
      If your Fiorini Industrial Equipment pump isn't starting, there could be several reasons. The pump motor might be damaged, in which case you should replace the pump. Another possibility is that there is no voltage, so you should check for voltage. Lastly, the pump could be jammed, and you'll need to unblock it.
  • S
    Steven SmithAug 20, 2025
    Why is my fiorini SET PLUS 2.0 - 25 Industrial Equipment pump making a noise?
    • S
      Stacy Whitehead MDAug 20, 2025
      If the Fiorini Industrial Equipment pump is making noise, it might be due to air in the hydraulic circuit, so you should vent air from the circuit. Another cause could be that the working point is outside the operating curve; adjust the calibration valve. Finally, check if there is an inverted phase in the power supply cable, and if so, invert the phases properly.
  • J
    Joshua GonzalesAug 25, 2025
    What causes the wrong flow rate in fiorini SET PLUS 2.0 - 25?
    • J
      Jason HortonAug 26, 2025
      If your Fiorini Industrial Equipment shows the wrong flow rate, the flow meter might be dirty, so you should clean the flow meter. It could also be defective, requiring you to replace it. Another potential cause is a wrong VFS type, so set the proper VFS type.
  • S
    Shannon GriffinAug 30, 2025
    How to fix noise and vibrations in Fiorini Industrial Equipment?
    • L
      Lisa VazquezAug 30, 2025
      If you're experiencing noise and vibrations in your Fiorini Industrial Equipment, it could be due to contact between metal parts, so check for it. Another potential cause is loose or missing screws, so add or tighten the screws.
  • B
    Beth HuntSep 4, 2025
    What to do if Fiorini Industrial Equipment has system low pressure?
    • E
      Edward MillsSep 4, 2025
      If your Fiorini Industrial Equipment system has low pressure, it might be due to leaks in the hydraulic circuit. Check and eliminate the problem.

fiorini SET PLUS 2.0 - 25 Specifications

General IconGeneral
Brandfiorini
ModelSET PLUS 2.0 - 25
CategoryIndustrial Equipment
LanguageEnglish