MANUAL for the basic control panel | CCB2.0
12. Alarms
List of alarms:
Internal card failure: SEF-025.1
Contact Technical Services
Replace battery and/or contact
Technical Services to reload the
program into RAM memory
Connection error or damaged
component
Check the connection and/or contact
Technical Services
Connection error or damaged
component
Contact Technical Services
Magneto-thermal
circuit breaker
Connection error, over current or lack
of phases
Check the connection, ensure the power
network is correct. Fault repaired: Reset
circuit breaker
The contact IN1 has not been closed
by the lamp sensor
Check the UV lamp sensor signal
Drain/emptying
motor-valve
Emptying confirmation time has
elapsed; no minimum level of water
detected
Check proper operation of the emptying
motor-valve
Fill confirmation time has elapsed; no
minimum level of water detected
Check proper operation of the water
supply solenoid valve
Drain/emptying
motor-valve
Established time has elapsed without
detecting feedback from the
drain/emptying motor valve
Check proper operation of the motor
valve feedback connection
Unable to reduce water conductivity
Check proper operation of the
conductivity sensor.
Check conductivity set-point
IN3 open, if external component
installed.
UV lamp
immersion in
basin
This lamp has been used for over
12,000 hours
Replace UV lamp with a new one. Reset
timer 12,000 h according to page 20
These alarms stop the operation of the equipment. Once you have resolved the problem,
you must turn the device off and on again to reset to initial status.