6. Remove page 5-3315-34 and insert changed page 5-3315-34
The drawing on page 5-34 has had the DO3 deactivated text added.
9. Remove page 5-39/540 and insert changed page 5-39/540
On page 5-39, a note is added regarding reversing the output signal
display.
10. Remove pages 5-57 thru 5-64 and insert changed pages 5-57 thru
5-64.
Page 5-57 has a change to the version number in subsection 5.17.
Page 5-56 also has a version number change. Page 5-60 in
Worksheet 5-2, the Calculation of Process Variable function has been
changed to show All as the first variable in the last two formulas. On
page 5-63, changes are made to FCODE 135 and 136.
11. Remove Appendix A page A-l /A4 and insert changed Appendix A
page A-llA4.
Fault code El 10 is added on page A-3.
12. Place this instruction page behind Page B, Change 2 List of Effective
Pages, as a record of Change 2 insertion.