The MASK Custom Function 5, adds the power of creating photographic digital masks that can be used in
layers within photo editing software, to mask subjects, isolating them from backgrounds
without the use of special computer based post production techniques. A great time saver.
You need to establish the link from the transmitting R2 Rapid or XPLOR 600 Custom Function corresponding
to the MASK feature. The concept is simple, while one set of ashes re for the main subject, the other set
ashes
immediately after in sequence to make 2 dierent exposures. The execution is precise when you follow the
linking process on each ash, assigning the N1 or N2 designation as needed.
There are two settings for the Custom Function on the eVOLV200.
N1: Mask function is on: when the camera res 2 shots rapidly, the units linked will trigger on the rst shot.
N2: Mask function is on: when the camera res 2 shots rapidly, the linked units will trigger on the second
shot.
MASK Custom Function 5
Troubleshooting
If there is a problem, refer to this Troubleshooting Guide.
The ash exposure is underexposed or overexposed.
There was a highly reective object (e.g. glass window) in the picture.
> Use FE lock (FEL).
You used high-speed sync.
> With high-speed sync, the eective ash range will be shorter. Make sure the subject is within the
eective ash range displayed.
You used Manual Flash mode.
> Set the ash mode to TTL or modify the ash output using a ash meter for accurate exposure.
The system provides real-time protection to secure the device and your safety. The following is a list
of prompts for your reference:
Other LCD Error Messages
Prompts on LCD Panel Meaning
E1
A failure occurred on the recycling system that prevents the ash from
ring.
Please restart the ash unit. If the problem still exists, please send this
product to our maintenance center.
E2 The system is excessively hot. Please allow a rest time of 10 minutes.
E3
The voltage on two outlets of the ash tube is too high. Please send
this product to our maintenance center.
E9
There are some errors that occurred during the upgrading process.
Please try again using the correct rmware upgrade method.