6.2.3 Adjusting the inlet sensor
Place a bottle so it is resting in the corner of the sluice rail (1).
Loosen the sensor screw (2) and move it to the right.
Watch the sensor indicator (see 5 - Control panel) and move the sensor to the left.
When the sensor light goes on fasten the sensor screw (2).
Move the bottle back (up in picture) and control that the sensor light does not go on before the
bottle is resting against the sluice railing (1).
If the sensor goes on too early move it a little to the right.
If the senor does not go on move it a little to the left.
6.2.4 Adjustment of the filling stand
Adjust the filling stand and the filling nozzle over the centre of the second bottle in the sluice.
The nozzle tip should only be a few millimetres above the bottle top to minimise spill and spray.
second bottle in outlet sluice