9.1.3 Alignment of trays
If the inlet tray or the outlet tray have become out of alignment the bottles will not glide easily.
The trays can be aligned as described in the installation section, see section 3.3.2.1, 3.3.2.3 or 3.3.2.5.
9.2 Service
Should service be needed, please contact W-M Flexicon or your local supplier.
9.3 Methods and frequency of inspections for safety functions
Safety functions should be tested once a year:
Emergency switch
When pressed the entire machine and the peripherals connected through the 2 power outlets are
turned completely off. Compressed air is switched off and released.
Ejector Safety Beam
The ejector safety beam can be pushed back without use of force.
Keep a log and read the previous log recordings to present an overview of the machines state.
After testing the safety functions the results must be recorded in the log.
10 Change of voltage
FF20 can be converted to accept another supply voltage.
The conversion is carried out inside the control box by moving the cables of the transformer clamps, to
the position indicated in the picture below.
Change of voltage