Technical data14
Measurement
Object temperature range
• –20°C to +150°C (–4°F to +302°F)
• 0°C to +650°C (+32°F to +1202°F)
Accuracy ±4°C (±7.2°F) or ±4% of reading, for ambient tem-
perature 10°C to 35°C (+50°F to 95°F)
Measurement analysis
Spotmeter
1
Automatic hot detection Heat detection mode (the hottest 20% of the of
scene is colorized)
Isotherm Yes
Set-up
Set-up commands Local adaptation of units, date and time formats
Languages English
Storage of images
Image storage Standard JPEG
Storage media Internal flash memory
Image storage capacity 200 files in total
NOTE
The total number of files is co-dependent on
the number of saved video clips.
Image storage mode IR only
File formats Standard JPEG
Image annotations
Report generation
Separate software (FLIR Tools)
Video recording in camera
Non-radiometric IR video recording
MPEG-4 to internal flash memory
Storage capacity 200 files in total, with a maximum duration of 5 mi-
nutes each.
NOTE
The total number of files is co-dependent on
the number of saved images.
Video streaming
Non-radiometric IR video streaming
Uncompressed colorized video using USB
USB
USB USB Mini-B
Compatibility
Compatible with FLIR software
FLIR Tools
Data communication interfaces
Interfaces
• Update from PC devices
• Data transfer to and from PC