Do you have a question about the FLIR TG165 and is the answer not in the manual?
Temperature Range | -25°C to 380°C (-13°F to 716°F) |
---|---|
Thermal Sensitivity | <150 mK |
Display | 2.0 in TFT LCD |
Battery Life | 5 hours continuous scanning |
Image Frequency | 9 Hz |
Distance to Spot Ratio | 24:1 |
Field of View | 50° x 38.6° |
Detector Type | Uncooled microbolometer |
Image Resolution | 80 x 60 pixels |
Battery Type | Rechargeable Li-ion battery |
Accuracy | ±1.5% or 1.5°C |
Laser Pointer | Single laser pointer for center of measurement area |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
Spectral Range | 8 – 14 μm |
Display Resolution | 320 x 240 pixels |
Operating Temperature | 0°C to 50°C (32°F to 122°F) |
Copyright notice for FLIR Systems, Inc. and terms of use for documentation.
Details FLIR Systems' ISO 9001 certification and commitment to continuous development.
Instructions on how to access the latest manuals and notifications from FLIR's support website.
Guidance on environmentally friendly disposal of electronic equipment according to regulations.
Explanation of symbols indicating the need to refer to the manual for further information.
Important warnings regarding meter use, laser pointer safety, and explosive environments.
Step-by-step instructions for basic operation, including powering on and taking measurements.
How to power on/off the TG165 and charge its battery using USB or AC adapter.
Explanation of the main display elements and icons for the IR thermal imaging.
Detailed description of the function of each button and the trigger on the TG165.
Procedure for pointing the TG165, activating lasers, and capturing temperature readings.
Instructions on how to save, discard, review, and delete captured IR images.
Highlights the main features of the TG165, including its dual lenses and display.
Explains how IR thermometers measure surface temperature and the concept of emissivity.
Identifies and describes the components on the rear of the TG165, including the display and buttons.
Identifies and describes the components on the front of the TG165, including lenses and trigger.
Details the compartment for Micro USB port and Micro SD card slot on the top of the TG165.
Describes the tripod mount and lanyard access located on the bottom of the TG165.
Information about the TG165's rechargeable battery and how the battery status icon is displayed.
Instructions for charging the battery via USB or AC source, both when the unit is ON or OFF.
Details the APO feature, which automatically shuts off the meter after a period of inactivity.
Procedure for forcing the TG165 to reset and power down if the display freezes.
Explains how to use the POWER/BACK button for power control and exiting menus.
Details the OK/MENU button's functions: accessing menus, confirming selections, and saving images.
Describes how to use the UP and DOWN arrow buttons for menu navigation and image review.
Explains that the trigger activates laser pointers and captures snapshots when released.
Procedure for powering on the TG165, including the startup screen and initial display.
Introduction to the Settings Menu, its purpose, and how settings are saved.
Information on battery replacement and contacting FLIR Systems for service.
Details about factory calibration and the process for required calibration.
Instructions for cleaning the housing, lenses, and display window using appropriate materials.
Details display, laser pointers, battery, data recording, certifications, and dimensions.
A table listing emissivity values for various common materials.
Details the terms and conditions of the FLIR Limited Warranty for imaging products.