EasyManua.ls Logo

Fluke 1537-II - Polarization Index (PI)

Fluke 1537-II
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Insulation Tester
Insulation Test Settings
Polarization Index (PI)
As part of the insulation test, the Tester measures and stores polarization index
(PI), when appropriate. A polarization index test requires 10 minutes to complete.
Therefore, the Tester will start a countdown at 10 minutes. When an insulation test
reaches 10 minutes, the polarization test is complete. The results are available for
display during a test or when you store the test results and view the record PI eld.
See
Figure 4
.
The eld is identied by:
min1
min10
R
R
PI =
Figure 4. Polarization Index (PI)
1 2
2x = PI
10 min.
min1
min10
R
R
PI =

Related product manuals