14
1535/1537/1537-II
Users Manual
Test Circuit Connections
XW
Warning
To prevent possible electric shock or personal injury:
• Disconnect power and discharge all high-voltage capacitors before
you measure resistance.
• Connect the Earth (E) test lead before the live (L) test lead and
remove the L test lead before the E test lead.
• Before and after tests, do a voltage test to conrm that the Tester
does not detect the presence of hazardous voltage. See
Table 3
. If
a hazardous voltage is shown on the display, remove power from
the circuit under test and disconnect test leads.
To connect to the circuit under test:
1. Put the test leads into the correct terminals. See
Table 4
.
2. Connect the test leads to the circuit under test.
Table 4. Test Lead Connections
30V
M
A
X
E
L
2
1
Item Description
1
E - Earth Terminal
2
L - Live Terminal