29
Insulation Tester
Electrical Specications
Table 11. Insulation Resistance Measurement
(cont.)
Test Voltage Range Resolution Accuracy
500 V
<200 kΩ unspecied unspecied
200 kΩ to 500 kΩ 1 kΩ 5 %
0.50 MΩ to 5.00 MΩ 0.01 MΩ 5 %
5.0 MΩ to 50.0 MΩ 0.1 MΩ 5 %
50 MΩ to 500 MΩ 1 MΩ 5 %
0.50 GΩ to 5.00 GΩ 0.01 GΩ 5 %
5.0 GΩ to 10.0 GΩ 0.1 GΩ 5 %
10.0 GΩ to 50.0 GΩ 0.5 GΩ 20 %
50 GΩ to 100 GΩ 5 GΩ 20 %
>100 GΩ unspecied unspecied
1000 V
<200 kΩ unspecied unspecied
200 kΩ to 500 kΩ 1 kΩ 5 %
0.50 MΩ to 5.00 MΩ 0.01 MΩ 5 %
5.0 MΩ to 50.0 MΩ 0.1 MΩ 5 %
50 MΩ to 500 MΩ 1 MΩ 5 %
0.50 GΩ to 5.00 GΩ 0.01 GΩ 5 %
5.0 GΩ to 20.0 GΩ 0.1 GΩ 5 %
20.0 GΩ to 50.0 GΩ 0.5 GΩ 20 %
50 GΩ to 200 GΩ 5 GΩ 20 %
>200 GΩ unspecied unspecied