Earth Ground Clamp
Electrical Specifications
23
Overload Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . OL
Data Logging Capacity. . . . . . . . . . . . . . . . . . . . . . . . .>2000 data points
Data Logging Interval . . . . . . . . . . . . . . . . . . . . . . . . . .1 second to 59 minutes and 59 seconds
Safety
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC 61010-1: Pollution Degree 2
IEC 61557-1
Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IEC 61010-2-032: CAT IV 600 V /
CAT III 1000 V
Current Clamp for Leakage Current
Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC 61557-13: Class 2, 30 A/m
Resistance to Earth. . . . . . . . . . . . . . . . . . . . . . . . . IEC 61557-5
Effectiveness of the Protective Measures. . . . . . . .IEC 61557-16: cutoff frequency 20 kHz (-3 dB)

Other manuals for Fluke 1630-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1630-2 and is the answer not in the manual?

Fluke 1630-2 Specifications

General IconGeneral
TypeEarth Ground Clamp Meter
Ground Resistance Range0.025 Ω to 1500 Ω
DisplayLCD
Data LoggingYes
Operating Temperature-10 °C to 50 °C
Storage Temperature-20 °C to 60 °C
Ground Resistance Accuracy±(1.5% + 0.02 Ω)
Jaw Opening32 mm
Power SupplyAA batteries
Safety RatingCAT IV 600 V