Electrical Specifications
Maximum Voltage to Earth Ground . . . . . . . . . . . . . . .1000 V
Battery Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AA alkaline IEC LR6 (x4)
Battery Life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>15 hours in Ground Resistance measurement mode, with backlight turned off, and
RF mode turned off
Frequency Range
Filter OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Hz to 1 kHz
Filter ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Hz to 70 Hz
Ingress Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . .IEC 60529: IP30 with jaw closed
LCD
Digital Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . .9999 counts
Refresh Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4/second
Temperature
Operating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-10 °C to +50 °C
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-20 °C to +60 °C
Operating Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . .Non condensing (<10 °C)
90 % RH (at 10 °C to 30 °C)
75 % RH (at 30 °C to 40 °C)
45 % RH (at 40 °C to 50 °C)
(noncondensing)
Altitude
Operating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2000 m
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 000 m
Reference Temperature . . . . . . . . . . . . . . . . . . . . . . . .23 °C ±5 °C (73 °F ±9 °F)
Temperature Coefficient. . . . . . . . . . . . . . . . . . . . . . . .0.15 % x reading/ °C (<18 °C or >28 °C)

Other manuals for Fluke 1630-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1630-2 and is the answer not in the manual?

Fluke 1630-2 Specifications

General IconGeneral
TypeEarth Ground Clamp Meter
Ground Resistance Range0.025 Ω to 1500 Ω
DisplayLCD
Data LoggingYes
Operating Temperature-10 °C to 50 °C
Storage Temperature-20 °C to 60 °C
Ground Resistance Accuracy±(1.5% + 0.02 Ω)
Jaw Opening32 mm
Power SupplyAA batteries
Safety RatingCAT IV 600 V