AC and DC Current Measurements
XWWarning
To prevent possible electrical shock or
personal injury, do not make an in-circuit
current measurement where the open-circuit
potential to earth is >1000 V. Meter damage
or injury can occur if the fuse blows during
such a measurement.
WCaution
To prevent possible damage to the Meter or
to the equipment under test:
Do a fuse test before current
measurements.
Use the correct terminals, function, and
range for all measurements.
Do not put the probes across (in parallel
with) a circuit or component when the
test leads are connected to the current
terminals.
To measure current, you must break the test circuit, then
put the Meter in series with the circuit.
The current ranges are 6.000 A, and 10.00 A. AC current
is shown as an rms value.
To measure current (see Figure 6):
1. Remove power from the circuit. Discharge all high-
voltage capacitors.
2. Put the black test lead into the COM terminal. Put the
red test lead into the A terminal.
3. Set the function switch to for ac current or for
dc current.

Other manuals for Fluke 233

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 233 and is the answer not in the manual?

Fluke 233 Specifications

Power IconPower
maximum voltage between terminal and earth ground1000 V rms
fuse for A inputs11 A, 1000 V 17000A interrupt rating
wireless frequency2.4 GHz ISM Band 10 meter range
Operating Environment IconOperating Environment
operating altitude2, 000 meters
storage altitude12, 000 meters
operating temperature-10 °C to +50 °C
storage temperature-40 °C to +60 °C
relative humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
Battery IconBattery
meter base battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
display module battery typeTwo AA Alkaline batteries, NEDA 15A IEC LR6
battery life400 hrs typical (Alkaline)