True-rms Remote Display Digital Multimeter 
  Maintenance 
29 
Maintenance 
XWWarning 
To prevent a possible electrical shock or 
personal injury, have an approved technician 
repair the Meter. 
General Maintenance 
Clean the case with a damp cloth and weak detergent. Do 
not use a solvent or cleaners with abrasives. 
Dirt or moisture in the terminals can cause incorrect 
measurements. To clean the terminals: 
1.  Turn the Meter off and remove all test leads. 
2.  Shake out dirt that can possibly be in the terminals. 
3.  Soak a clean swab with weak detergent and water. 
Move the swab around in each terminal. Dry each 
terminal with canned air to push the water and 
detergent out of the terminals. 
XWWarning 
To prevent electrical shock or personal 
injury, remove the test leads and all input 
signals before you replace the batteries or 
fuses. To prevent damage or injury, install 
ONLY specified replacement parts shown in 
Table 7. 
Battery Replacement 
XWWarning 
To prevent incorrect measurements, possible 
electrical shock, or personal injury, replace 
the battery when the battery indicator () 
appears. If the display shows  , the 
Meter will not function until the display 
module batteries are replaced. If the display 
shows  , the Meter will not function 
until the Meter base batteries are replaced. 
There are two low-battery indicators in the display: one 
for the Meter base batteries and one for the display 
module batteries. Replace the batteries when the low-
battery indicator shows.