27 II/28 II
Users Manual
18
Continuity Tests
WCaution
To avoid possible damage to the Meter or to
the equipment under test, disconnect circuit
power and discharge all high-voltage
capacitors before testing for continuity.
The continuity test features a beeper that sounds as long
as a circuit is complete. The beeper allows you to perform
quick continuity tests without having to watch the display.
To test for continuity, set up the Meter as shown in
Figure 4.
Press to turn the continuity beeper on or off.
The continuity function detects intermittent opens and
shorts lasting as little as 1 ms. A brief short causes the
Meter to emit a short beep.