417D/424D
Users Manual
14
Volume
To measure volume:
1. Push 2x.
The s symbol appears in the display.
2. Push to make the first measurement (for example,
length).
3. Push again to make the second measurement (for
example, height).
4. Push again to make the third length measurement (for
example, depth).
The result shows in the summary line.
5. Push x 2 seconds to show additional room information
such as ceiling/floor area, surface area of the walls,
circumference.
w Ceiling/floor area
v Wall area
u Circumference
Tilt
Note
The inclinometer senses tilts at 360
°
. For tilt
measurements, hold the Meter without a transverse tilt
(
±
10
°
).
Smart Horizontal Mode
Use the Smart Horizontal mode (indirect horizontal distance)
function to find a horizontal distance when the line-of-sight is
blocked by an object or obstacle. See Figure 7 for more
information.
The tilt is continuously shown as ° or %. To change the units,
push and hold at the same time for 2 seconds. The default
unit is °.
To measure:
1. Push 1x.
` shows in the display.
2. Point laser at target.
3. Push .
The display shows all results as α (angle f), x (diagonal
distance b), and y (vertical distance c). The z (horizontal
distance) shows in the summary line.
4. Push to turn off Smart Horizontal Mode.