417D/424D
Users Manual
22
Specifications
417D 424D
Distance Measurement
Accuracy at favorable conditions
[1]
±2.0 mm (±0.08 in)
[3]
±1.0 mm (±0.04 in)
[3]
Accuracy at unfavorable conditions
[2]
±3.0 mm (±0.12 in)
[3]
±2.0 mm (±0.08 in)
[3]
Range at favorable conditions
[1]
0.2 m to 40 m (0.6 ft to 131 ft) 0.05 m to 100 m (0.16 ft to 328 ft)
Range at unfavorable condition
[4]
30 m / 98 ft 60 m / 196 ft
Smallest unit displayed 1 mm / 1/16 in 1 mm / 1/32 in
laser point at distances
6 mm @ 10 m / 30 mm @ 50 m / 60 mm @ 100 m
0.24 in @ 33 ft / 1.2 in @ 164 ft / 2.4 in @ 328 ft
Tilt measurement
Measurement tolerance to laser beam
[5]
no ±0.2 °
Measurement tolerance to case
[5]
no ±0.2 °
Range no 360 °
Compass accuracy no
8 points (±22.5 °)
[6]
General
Protection class IP54
Automatic laser off 90 seconds
Automatic power off 180 seconds
Battery life (2 x AAA)
1.5 V NEDA 24A/IEC LR03
up to 3000 measurements up to 5000 measurements
Dimensions (H x W x L)
11.6 cm x 5.3 cm x 3.3 cm
(4.6 in x 2.1 in x 1.3 in)
12.7 cm x 5.6 cm x 3.3 cm
(5.0 in x 2.2 in x 1.3 in)
Weight (with batteries) 113 g (4 oz) 158 g (6 oz)
Temperature
Storage
-25 °C to +70 °C
(-13 °F to +158 °F)
-25 °C to +70 °C
(-13 °F to +158 °F)
Operation
0 °C to +40 °C
(32 °F to +104 °F)
-10 °C to +50 °C
(14 °F to +122 °F)
Calibration cycle Not applicable Tilt and Compass