712B/714B
Calibration Manual
Adjust 500 Ω Source...................................................................... 23
Adjust 3500 Ω Source.................................................................... 23
Adjust Trigger Current for Ohms Measure ........................................ 24
Adjust 0.1 mA Trigger Current....................................................... 24
Adjust 0.25 mA Trigger Current ..................................................... 25
Adjust 0.5 mA Trigger Current....................................................... 25
Adjust 1 mA Trigger Current.......................................................... 26
Adjust Ohms Measure....................................................................... 26
Adjust 50 Ω Input........................................................................... 27
Adjust 350 Ω Input......................................................................... 27
Adjust 500 Ω Input......................................................................... 28
Adjust 3500 Ω Input....................................................................... 28
Adjust mA Measure ........................................................................... 29
Adjust 0.1 mA Input ....................................................................... 29
Adjust 24 mA Input ........................................................................ 30
Adjust External Trigger for Ohms Source .......................................... 30
Adjust 0.1 mA External Trigger ...................................................... 31
Adjust 1 mA External Trigger......................................................... 31
Save Data and Reset the 712B System ............................................ 32
714B Calibration Adjustment................................................................. 32
Enter Calibration Mode...................................................................... 32
Use 8508A to Adjust the 5522A Output ............................................. 33
Adjust mV Source.............................................................................. 33
Adjust mV Measure ........................................................................... 34
Adjust Internal Cold Junction Temperature ....................................... 35
Use the Fluke 9101-256 ................................................................ 35
Use a Lag Bath.............................................................................. 37
Adjust mA Measure ........................................................................... 38
Save Data and Reset the 714B System ............................................ 39
User-Replaceable Parts and Accessories ............................................. 40
ii