Measuring Temperature 
The Meter measures the temperature of a type-K 
thermocouple (included). Choose between degrees 
Celsius (°C) or degrees Fahrenheit (°F) by pushing C.  
W Caution 
To avoid possible damage to the Meter or 
other equipment, remember that while the 
Meter is rated for –200.0 °C to +1090.0 °C and 
–328.0 °F to 1994.0 °F, the included K-Type 
Thermocouple is rated to 260 °C.  
Display ranges are –200.0 °C to +1090.0 °C and   
–328.0 °F to 1994.0 °F. Readings outside of these ranges 
show OL on the Meter display. When there is no 
thermocouple connected, the display also reads OL.  
To measure temperature, do the following: 
1.  Connect a type-K thermocouple to the Meter’s COM 
and dV eG
 terminals. 
2.  Turn the rotary switch to 
M. 
3.  Press A to enter temperature mode. 
4.  Push C to choose Celsius or Fahrenheit. 
Testing for Continuity 
WCaution 
To avoid possible damage to the Meter or to 
the equipment under test, disconnect circuit 
power and discharge all high-voltage 
capacitors before testing for continuity. 
The continuity test features a beeper that sounds as long 
as a circuit is complete. The beeper allows you to perform 
quick continuity tests without having to watch the display. 
To test for continuity, set up the Meter as shown in  
Figure 4. 
Press Eto turn the continuity beeper on or off. 
The continuity function detects intermittent opens and 
shorts lasting as little as 1ms. A brief short causes the 