EasyManua.ls Logo

Fluke 902 FC - Measure Capacitance; Measure AC Current

Fluke 902 FC
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
902 FC
Users Manual
18
Measure Capacitance
1. Turn off power to the circuit.
2. Disconnect and discharge the capacitor.
3.
Turn the rotary switch to
.
4. Take the measurement noting the correct polarity of
the
capacitor.
If the capacitor requires more discharging, diSC shows while the
capacitor discharges.
Measure AC Current
XW Warning
To prevent possible electrical shock, fire, or
personal injury:
Remove Test Leads before making cu
rrent
measure
ments.
Do not hold the Product anywhere beyond
the
tactile
barrier (see Figure 4).
1.
Turn the rotary switch to
.
2. Center the wire within the clamp jaws below the ho
rizontal line
located on the clamp (see Figur
e 4).
Note
Measure one wire at a time because currents moving in
different directions will cancel each other out (see
Figure 4).

Related product manuals