EasyManua.ls Logo

Fluke 902 FC - Specifications; Electrical Specifications

Fluke 902 FC
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
902 FC
Users Manual
26
Specifications
Electrical Specifications
Function Range Resolution Accuracy
Voltage DC 600 V 0.1 V 1.0 % ±5 counts
Voltage AC
(True-rms)
600 V 0.1 V
1.5 % ±5 counts,
(45 Hz to 400 Hz)
Current AC
(True-rms)
600 A 0.1 A
2.0 % ±5 counts,
(45 Hz to 65 Hz)
2.5 % ±5 counts,
(65 Hz to 400 Hz)
Max Crest Factor (50 Hz/60 Hz)
3 @ 180 A
2.5 @ 220 A
1.42 @ 600 A
Note: Add 2 % for C.F. >2
Current DC 200 μA 0.1 μA 1.0 % ±5 counts
Resistance
600 Ω
6000 Ω
60 kΩ
0.1 Ω
1 Ω
0.01 kΩ
1.0 % ±5 counts
Continuity <30 Ω -- --
Temperature
-40 °C to
400 °C
0.1 °C 1.0 % ±8 counts
Capacitance
100 μF
1000 μF
0.1 μF
1 μF
1.0 % ±4 counts