C. Layer Management
:
Create and name a new layer
: Delete selected layer
:
Rename selected layer
:
Sequence arrangement, the working sequence will
be from top to bottom
D. Power and Speed Setting
Parameters for commonly used material can be found
in the "Parameters…" drop down list. Customized
parameters can be set using "Save". Use "Manage"
to edit or remove saved parameters. Power is set by
percentage which means a 30W machine can output 30W
if the power setting is 100%. Speed is set by mm per
second. Execution count can be set to repeat the same
action on a single layer.
Parameters may vary with different materials. Try built-in
parameters on first run and then fine tune the parameters
for better results.
The power setting is recommended to not exceed 70% to
avoid drastic consumption of laser tube.