FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司
28
TA Traffic Announcement
(0, 1)
Indicates instantaneous presence (1) of traffic information during broadcasting.
When this value is set to 1 by external TA switch, the value specified by TA command has no effect.
When this value is set to 1 by TA command, the value set by external TA switch has no effect.
Switching the PROGRAM causes clearing of the TA flag.
Note: In some cases the RDS encoder drives the TP and TA flags automatically, mainly if EON feature
is enabled. This ensures that these flags are set correctly under all conditions.
TA=1
TATMOUT TA Timeout
(0
-
255)
1-255 - Specifies a maximum duration in minutes during which the TA parameter can remain at one (1).
Then the TA flag is set back to zero (0). External TA switch is edge activated.
0 - Disables the TA timeout feature. External TA switch is level controlled.
Note: The TATMOUT command doesn’t affect the EON1TA switching. The External EON1TA switch can be
level controlled only.
Note: If TP=0, the TA Timeout is always set to 0.
TATMOUT=1
TP
Traffic Program
(0, 1)
This is a flag to indicate that the tuned program carries traffic announcements. The TP flag must only be set
on programs that dynamically switch on the TA identification during traffic announcements. The signal shall
be taken into account during automatic search tuning.
Note: In some cases the RDS encoder drives the TP and TA flags automatically, mainly if EON feature
is enabled. This ensures that these flags are set correctly under all conditions.
TP=1
TPS
Traffic PS
Static text displayed on receiver during traffic announcements. Max. 8 characters long.
The TPS= command requires additional processing time of up to 400 ms for internal synchronisation with
RDS group order.
TPS=TRAFFIC
TPS=
Disables the Traffic PS
INIT
Initi
alization
Sets most parameters and services in actually selected Program to their default values. Does not
clear Messages and Scheduling items.
Apply for example if new blank EEPROM is placed on the board or if the RDS encoder was previously used
for another station.
INIT
Initialize the program bank that is actually selected.
*CC=
Complete initialization procedure. Replace the HH:MM with actual time and the
PROGRAM=2
DD.MM.YY with actual date.
INIT
Note: This initialization sequence must always be applied if new blank
*ALL
EEPROM is placed on the board in production process. Alternatively use the
PROGRAM=1
Windows control software: Options – Special – Initialize.
INIT
*ALL
TIME=HH:MM
DATE=DD.MM.YY
ALL
Sto
re All
Stores all settings in non-volatile EEPROM memory.
*ALL
HELP
Help
Shows all commands available.
HELP