EasyManua.ls Logo

Follett L78614 - Specifications; Electrical; Ambient; Plumbing

Follett L78614
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specications
air exhaust
16.00
"
(40.7 cm)
4.00
"
(10.2 cm)
3/8
" FPT
water inlet
3/4
" MPT drain
23.5
"
(59.7 cm)
18.00
"
(45.8 cm)
32.00
"
(82.6 cm)
air
intake
Front View Side View Rear View
22.625
"
(57.5 cm)
power cord (NEMA 5-15)
Electrical
§ 115 V, 60 Hz, 1 phase, 11.0A
§ Connect to a 15A dedicated circuit.
Ambient
Air temp* 100 F/38 C Max. 50 F/10 C Min. Best performance below 80 F (27 C)
Water temp
90 F/32 C Max. 45 F/4 C Min. Best performance below 70 F (21 C)
Water pressure (psi/bar) 70/5 Max. 10/0.7 Min.
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
12CI425A 12HI425A
Dispenser drain 3/4" MPT 3/4" MPT
Water inlet 3/8" FNPT 3/8" FNPT
Note: Water shut-off recommended within 10 ft. (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
§ 6" (15.3 cm) on right side of dispenser, 6" (15.3 cm) at top, and 12" (30.5 cm) at top recommended for service.
Note: Do not block right side air intake or top air exhaust.
Dry weight
§ 144 lb (65 kg)
4 12CI425A, 12HI425A

Related product manuals