POWER-UP:
Apply weight (press on platform or tank) and verify indicator NET WT responds.
START-UP CHECKLIST
QUESTIONS ? Help Hotline: 1-800-893-6723
W.3
File: T4\O&M\WIZ MSTR\WIZ NEW PR328 CHKOFF.tcw
03/21/08 MT
WIZARD 4000 INDICATOR
7
Scale display should read NET WT or NET REMAINING. Press DISPLAY SELECT
key as needed until display reads NET WT or NET REMAINING.
SCALE APPLICATIONS:
ULTRASONIC SENSOR (ECHO-SCALE) APPLICATIONS ONLY:
Enter tank diameter in SETUP MENU "17 TANK SETUP". See Page W.23B for details.
SET ZERO:
Enter USER MENU "8 SET ZERO" and follow prompts. See page W.15 for details.
(Indicator typically zero'd with empty tank and all other appurtenances installed.
For gas cylinders and ton containers, zero scale with empty platform).
CLEAR AMOUNT USED:
Enter USER MENU "3 CLEAR AMOUNT USED" and follow prompts. See page W.13 for details.
REVIEW TANK LOAD PROCEDURE:
See page W.7 for details.
AUTO REFILL WARNING!
If using AUTO REFILL OPTION (ARC), thoroughly review pages W.24 through W.26 to protect
against chemical spills!
REVIEW ALL MENU ITEMS:
Review all USER MENU and SETUP MENU items and change as required for your application.