WARNING !
DO NOT UNLOAD or LOAD tanks until "CHANGE TANKS NOW, THEN
PRESS ENTER" appears on the display. If you load or unload tanks
before reaching this step, the "AMOUNT USED" and "DAILY USAGE"
displays will be incorrect.
It also allows you to enter the tare weight(s) of your tanks if you choose "Manual" tank load mode, or load the
net weight of a cylinder if you chose the "Auto" tank load mode.
'TANK LOAD" key allows you to load new tanks without adversly
affecting the "AMOUNT USED" and "DAILY USAGE" displays.
Press "TANK LOAD" key to enter the tank load mode.
Remove empty tanks and place new tank(s) onto the scale
then press "ENTER" key to continue.
#2 TANK #1 TARE
#1 NET = 0 LB
#2 NET = 1950 LB
ARE YOU SURE
....If you chose "AUTO" the WIZARD automatically loads the
net weight and goes into the weighing mode (skip Step 6).
CHANGE TANKS NOW
THEN PRESS ENTER
WAIT
TANK TARE
*AUTO MANUAL
Verify you would like to continue tank load procedure.
Press "MENU" arrow keys to select which method, then press "ENTER".
MANUAL Mode: Requires that you enter tare weight of EACH tank on
EACH scale. (Example: Scale #2, tare weight of TANK #1is 1234 lbs.,
then TANK #2, etc). After entering the tare weights of all your tanks, the
WIZARD 4000 automatically adds them up and subtracts them from
the gross weight.
Step 6
Digital Display Action Required - Press "ENTER" after completing each step.
Step 2
Step 4
Step 5
Step 3
Step 1
....If you chose "MANUAL" you will manually enter tank
tare weight in Step 6.
....If MANUAL chosen above in Step 3...
Use "MANUAL" for PARTIALLY FULL containers.
Use "AUTO" for FULL containers.
TANK LOAD MODE
Fill your tank with chemicals, then press "ENTER" key to continue.
FILL TANK NOW
THEN PRESS ENTER
Step 7
"PORTABLE" Tank Applications (follow Steps 1 thru 6 only), such as
Ton Containers, Drums and Cylinders.
"PERMANENT" Tank Applications (follow Steps 1, 2 and 7 only), such as
Chem-Scale, Hoppers, Procells and Ultrasonic
Skip to STEP 7 in "PERMANENT" Tank Applications.
QUESTIONS ? Help Hotline: 1-800-893-6723
W.7
File: T4\NEW O&M 2007\W7 WIZ NEW DAY1C.tcw
NO *YES
LBS = 1234
SELECT CHANNEL
Use "MENU" arrow keys, to choose channel, press "ENTER"
to accept the channel you want to load/unload tanks. This
"freezes" or "holds" the AMOUNT USED and DAILY USAGE
displays until tank load procedure finishes.
Step 2
, enter CH# 1
WIZARD 4000 TANK LOAD PROCEDURE:

Other manuals for Force Flow WIZARD 4000