34
508FS Basic Operation (continuation)
Operating Procedures - Quick start guide
• Once the plastic has cooled sufficiently the RELEASE button may be pressed to blow the moulding off
the mould. Too long or too soon a release may distort the moulding.
• At the appropriate time when the plastic has formed around the mould tool the fans may be turned on to
start the plastic cooling process – press the FAN button . When the moulding is adequately cooled, press
the fan icon again to turn it off.
• Once released the moulding is now complete and the table may be lowered. Ensure the table has reached
its lower position. Release the clamp frame to remove the moulding for inspection.
Review the results and determine the parameters required to produce the forming. Use the save settings
feature to set and record the values for later recall.