5
95
4.A"DEGRADED VOLUME DETECTED" screen pops out asking you to select a new
harddiskforrebuilding.Here,weselectST74.5GB.Press<Enter>toselectit.
5.ItgoesbacktoMainmenuwitha"Rebuild"statusofRAID5volume.Eventually,
a replacement hard disk has to join in and it always keeps three hard disks in the
RAID5system.
6. Operating System will perform the rebuilding later.
Intel(R)MatrixStorageManageroptionROMv5.0.0.1011ICH9RwRAID5
Copyright(C)2003-04IntelCorporationAllRightsReserved.
1. Create RAID Volume
2.DeleteRAIDVolume 4.RecoverVolumeOptions
5.Exit
RAID Volume :
ID Name Level Stripe Size Status Bootable
0 TryRAID5 RAID5(Parity) 64KB 149.1GB0 TryRAID5 RAID5(Parity)64KB 149.1GB Rebuild Yes
Physical Disks:
Port Drive Model Serial # Size Type/Status(Vol ID)
0 Hitachi HDS72161 PVF904�21G2J�M 149.0GBHitachiHDS72161 PVF904�21G2J�M 149.0GB PVF904�21G2J�M 149.0GB MemberDisk(0)
1
ST380811AS
5PS1TAGW 74.5GB MemberDisk(0)
2
SAMSUNG HD161HJ
S0V3J9APA30524 149.0GBS0V3J9APA30524 149.0GB 149.0GB Non-RAID Disk
3
ST380815AS
5RW1CA37
74.5GB MemberDisk(0)
Volume with “Rebulid” status will be rebuilt within the operating system.
Intel(R)RapidStorageTechnology-OptionROM-10.0.0.1032
Copyright(C)2003-10IntelCorporation.AllRightsReserved.
[ DISK/VOLUME INFORMATION ]
[ MAIN MENU ]
3. Reset Disks to Non-RAID
[↑↓]-Select[ESC]-Exit[ENTER]-SelectMenu
Intel(R)MatrixStorageManageroptionROMv5.0.0.1011ICH9RwRAID5
Copyright(C)2003-04IntelCorporationAllRightsReserved.
1.CreateRAIDVolume 4.RecoverVolumeOptions
2.DeleteRAIDVolume 5.AccelerationOptions
3. Reset Disks to Non-RAID 6. Exit
RAID Volume :
ID Name Level Stripe Size Status Bootable
0 TryRAID5 RAID5(Parity) 64KB 149.1GB0 TryRAID5 RAID5(Parity)64KB 149.1GB Normal Yes
Physical Disks:
Port Drive Model Serial # Size Type/Status(Vol ID)
0 Hitachi HDS72161 PVF904�21G2J�M 149.0GBHitachiHDS72161 PVF904�21G2J�M 149.0GB PVF904�21G2J�M 149.0GB MemberDisk(0)
1
ST380811AS
5PS1TAGW 74.5GB MemberDisk(0)
2
SAMSUNG HD161HJ
S0V3J9APA30524 149.0GBS0V3J9APA30524 149.0GB 149.0GB Non-RAID Disk
3
ST380815AS
5RW1CA37
74.5GB Non-RAID Disk
Intel(R)RapidStorageTechnology-OptionROM-10.0.0.1032
Copyright(C)2003-10IntelCorporation.AllRightsReserved.
[ DISK/VOLUME INFORMATION ]
[ MAIN MENU ]
[↑↓]-Select[ESC]-Exit[ENTER]-SelectMenu
"Degraded" volume and disk available for rebuilding detected. Selecting
a disk initiates a rebuild. rebuild completes in the operating system.
Select the port of the destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
2SAMSUNGHD161HJ S0V3J9APA30524 140.9GB
3ST380815AS 5RW1CA37 74.5GB
[ DEGRADED VOLUME DETECTED ]
3 ST380815AS 5RW1CA37 74.5GB3ST380815AS 5RW1CA37 74.5GB
[↑↓]-Previous/Next[ENTER]-Select[ESC]-Exit