IN-GNC03/4/5/6 - 15 - © Future Products Group
TROUBLE SHOOTING
Well does not operate/start
The mains isolating switch on
the wall, circuit breaker or fuses
are off at the power board
Turn isolating switch circuit
breaker or fuses on
High condenser temperature
Clean condenser and radiator
The power switch on the cabinet
is OFF
The power switch is faulty
Well does not reach correct
temperature
Air grills not fitted correctly
Ensure vanes are horizontal
Product blocking air grill
Fan cover not fitted correctly
Make sure there are no air gaps
Evaporator coil fins blocked
Clean coil fins of food etc.
Trays obstructing air flow
Re-position trays on shelves
Thermostat needs adjustment
Ambient temperature > 25C
Adjust room air conditioning
Condenser radiator blocked
Temperature probe damaged
Replace temperature probe
Have defrost settings checked
Have fans checked/replaced
The table entries in italics indicate actions to be taken only by qualified Service
Personnel.