7 MOUNTING AND INSTALLATION
7.1 Correct Site of Installation
Ambient conditions
Site of installation
Indoors, in enclosed buildings
Not exposed to direct sunlight
No vibrations
External magnetic fields are allowed in the magnitude of the earth’s magnetic field only
Type of installation
Screwing connection to a compatible Franka Emika robot’s end effector flange
Protection class
IP 20 (according to EN 60529:1991)
Ambient medium
Air
Free from flammable substances (dust, gas, liquid)
Free from aggressive media
Free from corrosive substances
Free from “flying parts”
Free from spraying liquids
Free from pressurized airstreams
Pollution degree
Degree 2 (according to IEC 60664)
Only dry, non-conductive pollution occurs; occasionally temporary conductibility caused by condensation
may occur.
Ambient temperature
+15 °C to 25 °C (typical)
+5 °C to + 45 °C (extended)
-10 °C to + 60 °C (transport)
+5 °C to + 25 °C (storage)
Relative air humidity
20 % - 80 %, non-condensing
Set-up altitude
<= 2000 m above sea level