NOTICE
The Control contains power electronic components and modules (electric dri-
ves, CPUs, etc.) which heat up depending on the stress the device is subject
to. An internal, active ventilation system sucks in air from the environment
and channels it through the casing of the Control.
Therefore:
• make sure that the Control is adequately ventilated
• make sure there is enough distance between the front ventilators and
covering components
• make sure there is enough distance between the back ventilators and
covering components
• make sure that the ventilators are not blocked by pollution
• make sure the control is not exposed to direct sunlight
NOTICE
If a fuse in the upstream power supply of the Control blows, Panda is dis-
connected from the power supply. The Arm reacts with braking as much as
possible before the fail-safe locking bolts catch in the 7 axes. If the residual
energy is not sufficient to bring the Arm to a full stop, the locking bolts may
damage the Arm.
Therefore:
• the mains fuse is to be selected accordingly
Adequate ventilation
CORRECT SITE OF INSTALLATION