6 | Installation Franke Kaffeemaschinen AG
30 User manual A1000
Feet 40 mm (standard)
Feet 7 mm (option)
Feet 70 mm (option)
Feet 100 mm (option)
Adjustable feet can be used to compensate for unevenness or differences in height.
6.3 Requirements of the water supply
6.3.1 Main water connection
Water pressure 0,8-8,0 bar
Flow rate >100 ml/s
Water temperature <25 °C
Connection to the main water connection G3/8" compression fitting and metal hose l=1500
mm
Only connect with the hose kit provided
The main water connection must meet the requirements of the technical data and comply with appli-
cable federal, state, and local regulations.
The main water connection must have a backflow prevention device.
The main water connection must be equipped with a shut-off valve and a check valve with an up-
stream filter accessible for inspection. It must be possible for the filter to be removed for cleaning.
Water from the household decalcification system must not be used.
Filter with at least 100 loops/inch (UL)
6.3.2 Water quality
Total hardness: 4–8° dH GH (German total hardness)
7–14° fH GH (French total hardness)
4,2–8,3GPG
70–140ppm(mg/l)
Carbonate hardness 3–6°dHKH / 50–105ppm (mg/l)
Acid content/pH value 6.5–7.5pH
Chlorine content < 0.5mg/l
Chloride content < 30mg/l
TDS (total desolved solids) 30–150ppm(mg/l)
Electrical conductivity (measured) 50–200µS/cm (microsiemens)
Iron content < 0.3mg/l
Color: Clear
Taste: Fresh and pure taste
Aroma: No perceptible aroma
No rust particles in the water
Reverse osmosis: The water must have a dissolved solids content of at least 30-50 ppm (30-50 mg/l)
in order to prevent the boiler being overfilled.

Table of Contents

Other manuals for Franke A1000