6 INSTALLATION
6.1 Preparations
Installation site
– The installation site must fulfil the requirements of the permitted ambient conditions and must not be
located outdoors.
– The surface on which the machine is installed must be flat and level.
– Details regarding the space requirements and the hole dimensions can be found in the section entitled
Dimensions of the A300 [ 23] Electrical connection
– The outlet must be permanently installed at the installation site.
– The outlet must have a suitable connected load and fuse. The required connection values can be found on
the type plate of the coffee machine.
– The power connection for the coffee machine must be protected using a residual current circuit-breaker
(RCCB).
– The power outlet must be within reach of the power cord.
– No extension cord may be used to connect with the socket. Wastewater connection (optional)
– The wastewater connection must be equipped with a siphon.
– The siphon must be within reach of the wastewater hose.
– The siphon and the placement of the wastewater hose must be lower than the coffee machine itself. –
The connection to the siphon must use a free-flowing section of hose. Fixed water connection (optional)
– The mains water connection must be within reach of the water hose.
– The mains water connection must be clean and rinsed.
6.2 Dimensions of the A300
All dimensions are specified in mm.
Installation | 6
A300 with mains water connection