6 INSTALLATION
6.1 Preparations
Installation site
The installation site must fulfil the requirements of the permitted ambient conditions and must not be
located outdoors.
The surface on which the machine is installed must be flat and level.
Details regarding the space requirements and the hole dimensions can be found in the section entitled
Dimensions of the A300 [ 23] Electrical connection
The outlet must be permanently installed at the installation site.
The outlet must have a suitable connected load and fuse. The required connection values can be found on
the type plate of the coffee machine.
The power connection for the coffee machine must be protected using a residual current circuit-breaker
(RCCB).
The power outlet must be within reach of the power cord.
No extension cord may be used to connect with the socket. Wastewater connection (optional)
The wastewater connection must be equipped with a siphon.
The siphon must be within reach of the wastewater hose.
The siphon and the placement of the wastewater hose must be lower than the coffee machine itself.
The connection to the siphon must use a free-flowing section of hose. Fixed water connection (optional)
The mains water connection must be within reach of the water hose.
The mains water connection must be clean and rinsed.
6.2 Dimensions of the A300
All dimensions are specified in mm.
Installation | 6
A300 with mains water connection
270