Franke Kaffeemaschinen AG
User manual A300 27
Counter feedthrough Clearances at the top and rear
Installation | 6
Minimum clearances
To the rear wall: 50 mm
Above: 200 mm (for filling and removal of the bean hopper)
To the right: 100 mm (for opening the door)
6.3 Requirements of the water supply
6.3.1 Water connection
Water pressure
80800 kPa (0.88.0 bar)
Flow rate
> 0.1 l/sec
Water temperature
< 25 °C
Connection to the mains water connection
Union nut G3/8 and metal hose l = 1.5 m
Only connect with the hose kit provided
The mains water connection must meet the requirements of the technical data and comply with applicable
federal, state, and local regulations.
The mains water connection must have a backflow prevention device.
The mains water connection must be equipped with a shut-off valve and a check valve with an upstream filter
accessible for inspection. It must be possible for the filter to be removed for cleaning.
Water from a decalcification system must not be used.
Filter with at least 100 loops/inch (UL)
6.3.2 Water quality