EasyManua.ls Logo

Franke A300 - Connecting the Wastewater; Connecting Electrical Circuit

Franke A300
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User manual A300 27
6. Check the mains water connection for absence of leaks.
6.6 Connecting the wastewater
āœ“ The components for securing the wastewater hose are
present.
1. Connect the wastewater hose to the coffee machine.
2. Insert the wastewater hose into the siphon (hygiene
barrier) so that there is a free flow path [1] of at least 50 mm. The siphon still has to be ventilated.
3. Secure the wastewater hose in this position [arrow] to prevent it from sliding further into the siphon or
from being pulled out accidentally.
6.7 Connecting electrical circuit
4. Pour water into the drip tray and check the
drain.
WARNING
Risk of fatal injury from electrocution
Connecting to a power supply without a ground fault protective device can result in fatal injury from electrocution.
a) Ensure that the connection to the power supply is protected by a ground fault protective device.
WARNING
6
| Installation
Franke Kaffeemaschinen AG
1
Coffee machine
2
Strainer with seal
3
Coffee machine fitting
4
Water system fitting
5
Seal
6
Water hose
1.
Rinse the water hose and the water supply line
thoroughly to remove any dirt or debris.
2.
Connect the water hose with the strainer to the coffee
machine.
3.
Connect the water hose with the seal to the water
system.
4.
Fasten the screw joints hand
-
tight.
5.
Open the w
ater supply.