Franke Kaffeemaschinen AG Individualization and data transfer | 11
User manual SB1200 77
11.5.7 Cup monitoring
The parameters of the cup monitoring do not appear if the coffee machine has a camera-based (optical)
cup recognition.
Parameter Value range Remarks
During rinsing – Yes
– No
During drink preparation – Yes
– No
11.5.8 Transaction approval (API)
Parameter Value range Remarks
Activate transaction approval – Yes
– No
Allow Remote Control – Yes
– No
11.6 Loading/backing up data
11.6.1 Back up data
Desired action Menu item Information/instruction
Export a configuration
and media
3.1 Back up data – Export configuration
– Back up Franke media
– Back up your own media
– Eject USB stick automatically
– Display of file name
11.6.2 Load data
Desired action Menu item Information/instruction
Import configuration and
media
3.2 Load backup – Load backed up data (configuration, Franke me-
dia, your own media)
– Eject USB stick automatically

Table of Contents