TCP Client IP
Web Parameter IPAddress & Port in the TCPClient Settings section of the Serial Setup
page.
Network Type: Both
Default Setting: 0.0.0.0
Options: Any valid IP address.
Description: The IP address the transceiver creates a connection to on boot-up, when the
transceiver is set to TCP Client mode. In the configuration Web page, enter
the IP address to the left of the colon and the TCP port number in the box to
the right of the colon.
TCP Client Port
Web Parameter IPAddress & Port in the TCPClient Settings section of the Serial Setup
page.
Network Type: Both
Default Setting: 0000
Options: Any valid port number between 0 and 65335.
Description: The port number the transceiver creates a connection to on boot-up, when the
transceiver is set to TCP Client mode. In the configuration Web page, enter
the IP address to the left of the colon and the TCP port number in the box to
the right of the colon.
TCP Server Enable
Web Parameter: Mode in the Terminal Server Configuration section of the Serial Setup page.
Network Type: Both
Default Setting: Disabled
Options: Disabled, Enabled
Description: Enabling this parameter sets the operating mode of the transceiver's terminal
server to TCP Server. Your selection determines which other parameters are
available for the serial port.
TCPServer Inactivity Timeout
Web Parameter: Inactivity Timeout in the TCPServer Settings of the SerialSetup page.
Network Type: Both
Default Setting: 10
47