❒ Open the insulated door and push the locking lever up
❒ Pull out the ash container and put the cover plate provided onto the flange of the
ash container
❒ Take the ash container to the emptying point and empty it
➥ To remove the cover the clamp must be unlocked and opened
Check the grate and combustion chamber
NOTICE! Only clean the grate and combustion chamber when the boiler has cooled
down!
For P4 Pellet 15/20/25:
❒
Open the insulating door, open the ash door on the right and pull out the ash
drawer
For P4 Pellet 32/38/48/60/80/100/105:
❒ Open the insulating door, take out the ash container on the right and open the ash
door
❒ Check the combustion grate and combustion chamber for dirt
4
Boiler Servicing
Inspection and cleaning