Clean the fan wheel from the inside out using a soft brush or paint brush
Remove dirt and deposits from the induced draught housing using a scraper
Remove any ash which has gathered using an ash vacuum
Fit the induced draught fan
Plug in the connection cable and secure with cable ties
Cleaning the flue gas pipe
Unplug the connection cable of the induced draught fan
This prevents damage to the fan from the cleaning brush
Remove the inspection cover on the connecting pipe
Clean the connecting pipe between the boiler and chimney with a chimney
sweeping brush
Depending on the layout of the flue gas pipes and the chimney draught,
cleaning once a year may not be enough!
Plug in the connection cable of the induced draught fan
Cleaning the flue gas temperature sensor
1. Remove the insulating cover and thermal insulation
2.
Release the retaining screw and remove the flue gas temperature sensor from the
flue gas pipe
3. Wipe the flue gas temperature sensor with a clean cloth
4. Push in the flue gas temperature sensor until about 20 mm of the sensor remains
protruding from the bushing and secure with fixing screw