4.3 Emissions measurement by chimney sweep or regulatory body
Various legal regulations stipulate that heating systems must be inspected
periodically. In Germany this is regulated by the First Federal Emissions Protection
Ordinance (BimSchV) in the last amended version, and in Austria by various state
laws.
The following minimum requirements must be met by the operator of the system for a
successful measurement:
Thoroughly clean the boiler immediately before the measurement
Only use fuels of high quality which meet the requirements as stipulated in the
boiler operating instructions (“Permitted fuels” chapter)
Ensure that there is adequate heat consumption on the day of the measurement.
(e.g. storage tank must be able to take heat for the duration of the measurement)
4.3.1 Switch on the system
When the cleaning is complete:
Reassemble all dismantled components in reverse order and check for tightness
and correct installation
1. Turn on the main switch
2. Switch the boiler on by tapping “Boiler ON”
4.3.2 Emissions measurement by chimney sweep or regulatory body
Immediately before the start of the measurement:
Activate “Chimney-sweep mode” in the quick menu
The flue gas temperature and residual oxygen content should have stabilised
approximately 20 minutes after activation
The display will indicate that the boiler is ready for measurement
4
Boiler Servicing
Emissions measurement by chimney sweep or regulatory body
34 Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com