Cleaning the combustion space and combustion chamber
Activate service mode before starting inspection and cleaning work
In the quick menu activate “Service mode”
The controller follows the shutdown procedure and starts with the cleaning
cycle
After the cleaning cycle the boiler switches to the "Cleaning possible" operating
status
The tipping grate remains in the open position
Turn off the main switch
WARNING
Inspection and cleaning work on a system which is operational:
Risk of serious injuries from automatic startup of the system and severe burns
from hot parts and the flue gas pipe!
When working on the system:
always wear protective gloves
only operate the boiler using the handles provided
switch off the boiler by tapping “Boiler off” at the mode icon
The boiler follows the shutdown procedure and switches to “Boiler
off“ status
switch off the main switch and take precautions to prevent accidental
switching on
allow the boiler to cool off for at least 1 hour
once all of the tasks have been completed, turn the main switch back on and
switch the boiler on in the desired mode
Cleaning the combustion space and combustion chamber
Open the insulated doors and heat exchanger door
Remove the bulk of the ash from the combustion space with a shovel
Clean the combustion chamber sensor with a soft brush