EasyManua.ls Logo

Froling TX 200 - Cleaning the Combustion Space and Combustion Chamber

Froling TX 200
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cleaning the combustion space and combustion chamber
Activate service mode before starting inspection and cleaning work
❒ In the quick menu activate “Service mode”
➥ The controller follows the shutdown procedure and starts with the cleaning
cycle
➥ After the cleaning cycle the boiler switches to the "Cleaning possible" operating
status
➥ The tipping grate remains in the open position
❒ Turn off the main switch
WARNING
Inspection and cleaning work on a system which is operational:
Risk of serious injuries from automatic startup of the system and severe burns
from hot parts and the flue gas pipe!
When working on the system:
❒ always wear protective gloves
❒ only operate the boiler using the handles provided
❒ switch off the boiler by tapping “Boiler off” at the mode icon
➥ The boiler follows the shutdown procedure and switches to “Boiler
off“ status
❒ switch off the main switch and take precautions to prevent accidental
switching on
❒ allow the boiler to cool off for at least 1 hour
❒ once all of the tasks have been completed, turn the main switch back on and
switch the boiler on in the desired mode
Cleaning the combustion space and combustion chamber
❒ Open the insulated doors and heat exchanger door
❒
Remove the bulk of the ash from the combustion space with a shovel
❒ Clean the combustion chamber sensor with a soft brush
Boiler Servicing
4
Inspection and cleaning
Operating Instructions TX 200-250 | B1060217_en 35

Table of Contents