24
Copying all or part of this manual in any way or form is strictly prohibited without written permission from its author © 2015
website: www.fromm-pack.com
24 ALARM WARNING ON THE DISPLAY
The machine features a self-diagnosis system: in the event of an anomaly, sensors transmit signals to the system.
The system uses codes to identify the various anomalies. The table below indicates the code, type of anomaly
causing the alarm and the actions that must be taken.
Out of film. The film roll is empty.
The film is off the nozzle.
The teflon or silicone belt is broken.
Replace the roll of film and load it onto the
machine.
Repeat the film loading operation (section
21.5).
Replace the teflon or silicone belt.
The front sensor has detected an
accumulation of pillows near the output
rollers.
Remove the accumulated pillows to free the
sensor. The machine will restart in automatic
mode.
Machine operation inhibited by remote
control
Overheating. The machine reached an
excessively high temperature and was
automatically stopped.
After the necessary cooling period had
passed, press the START button. If the error
persists, call Technical Assistance and provide
the error code.
The remote sensor (basket) has
detected an accumulation of pillows in
the basket.
Remove the accumulated pillows to free the
sensor. The machine will restart in automatic
mode.
The machine has filled the maximum
number of meters set in the counter for
scheduled maintenance.
Contact Technical Assistance to have general
maintenance performed on the machine.
25 INFORMATION REGARDING NOISE
For machines identical to this machine, noise has been measured during pillow production using 25 micron film, at 1.6
m from the ground and at 1.5 meters from the machine. The following maximum values were measured:
Continuous sound level pressure
(SLP) equivalent weighted A
These values may vary by a maximum of 5% due to environmental and production factors.
26 MAINTENANCE
Maintenance operations that are performed with the safety guards removed must be performed when the machine is
shut off and disconnected from the power supply.
Maintenance personnel qualifications
The operator performing the mechanical and electrical maintenance phases must have completed a theoretical and
practical training course that includes the following: