70
Technical data
Operating envi-
ronments
Technical data
230V
Transport, storage or operation of the charger outside the stipulated area will
be deemed improper. The manufacturer shall not be held liable for any dam-
age arising from such usage.
Ambient temperature range:
- during operation: -10 °C to +40 °C (14 °F to 104 °F)
- during transport and storage: -20 °C to +55 °C (-4 °F to 131 °F)
- recommended temperature range during charging: + 4 °C to + 40 °C (+
39,2 °F to + 104 °F)
Relative humidity:
- up to 50 % at 40 °C (104 °F)
- up to 90 % at 20 °C (68 °F)
The surrounding air must be free from dust, acids, corrosive gases or sub-
stances, etc.
Can be used at altitudes up to 2000 m (6561 ft.)
Mains voltage ~ 230 V AC, ±15%
Mains frequency 50 / 60 Hz
Mains current max. 9.5 A eff.
Mains fuse max. 16 A
Efficiency max. 95%
Effective power max. 1100 W
Apparent power max. 2370 VA
Power consumption (standby) max. 2.1 W
Protection class I (with PE conductor)
Maximum permitted mains impedance at the inter-
face (PCC) to the public grid
none
EMC emission class A
Mark of conformity CE
Output voltage range 30 - 58 V DC
Output current max. 18 A DC
Output power max. 1040 W
Cooling Convection and fan
Dimensions l x w x h 270 x 168 x 100 mm
Weight (without cable) approx. 2 kg
Protection class IP43S
Overvoltage category
Device may only be operated on neutral-earthed
systems.
II