Special 2-step (US control panel only) - for selecting jobs and groups by pressing the
torch trigger
Press once (< 0,5 s)... next job in a group is selected
Press twice (< 0,5 s)... next group is selected
r
r (resistance) - Welding circuit resistance (in mW)
see "Measuring welding circuit resistance r"
L
L (inductivity) - Welding circuit inductivity (in microhenry)
see "Displaying welding circuit inductivity L"
COr
Correction - Gas correction ("Digital gas control" option)
Unit -
Setting range AUT/1.0 - 10.0
Factory setting AUT
NOTE!
Please refer to "Digital gas control" operating instructions for more detailed
explanations of the "COr" parameter.
EnE
Real Energy Input – electrical energy of the arc relative to the welding speed
Unit kJ
Setting range ON/OFF
Factory setting OFF
Since the full range of values (1 kJ - 99999 kJ) cannot be displayed on the three-digit
display, the following display format has been selected:
Value in kJ
1 to 999
1000 to 9999
10000 to 99999
Indicator on display
1 to 999
1.00 bis 9.99 (without the unit digit, e.g. 5270 kJ -> 5.27)
10.0 bis 99.9 (without the unit digit and the tens digit, e.g.
23580 kJ -> 23.6)
Parameters for
operating power
sources in paral-
lel in the Setup
menu level 2
P-C
Power Control - for defining the Master or Slave power sources when two power
sources are operated in parallel
Unit -
Setting range On (Master power source), OFF (Slave power source)
Factory setting OFF
NOTE!
The P-C parameter is only available when two power sources are connected via an
LHSB (LocalNet High-Speed Bus).