hot | H2O
Thermostat on cooling unit has tripped
Wait until the end of the cooling phase, i.e. until "Hot | H2O" is no longer dis-
played.
ROB 5000 or field bus coupler for robot control: Before resuming welding,
initialise the "Source error reset" signal.
Cause:
Remedy:
no | Arc
Arc break
Shorten the wire stick-out; press the torch trigger repeatedly;
clean the surface of the workpiece
Cause:
Remedy:
no | GAS
The “Gas watchdog” option has detected that there is no gas pressure
Connect a new gas cylinder and open the gas cylinder valve/pressure regu-
lator;
Acknowledge no | GAS by pressing the Store button
Cause:
Remedy:
no | IGn
Ignition time-out function is active: No current started flowing before the
length of wire specified in the Setup menu had been fed. The safety cut-out
of the power source has been triggered.
Shorten the wire stick-out; press the torch trigger repeatedly; clean the sur-
face of the workpiece; if necessary, increase the setting in “Setup menu:
Level 2” for the length of wire that is fed before the safety cut-out is
triggered.
Cause:
Remedy:
no | H2O
Cooling unit flow watchdog has been triggered
Check the cooling unit; top up with coolant or bleed the water flow if neces-
sary (see cooling unit operating instructions). Then acknowledge the error
by pressing the Store button
Cause:
Remedy:
no | Prg
No preconfigured program has been selected
Select a configured program
Cause:
Remedy:
r | E30
r-calibration: There is no contact with the workpiece.
Connect the grounding (earthing) cable; ensure a tight connection between
the contact pipe and the workpiece
Cause:
Remedy:
r | E31
r-calibration: Procedure has been interrupted by repeated pressing of the
torch trigger.
Ensure a tight connection between the contact tube and the workpiece
press the torch trigger once only
Cause:
Remedy:
r | E32
r-calibration: Grounding (earthing) cable, current cable or hosepack defect-
ive (value is below 0.5 mOhm or exceeds 30 mOhm)
Check grounding (earthing) cable, current cable or hosepack and replace if
necessary
Cause:
Remedy:
r | E33
r-calibration: Poor contact between the contact tube and the workpiece.
Clean the point of contact, tighten the contact tube, check the grounding
(earthing) connection
Cause:
Remedy:
181
EN
Toowoomba Welding Supplies : tweld.com.au : Ph +61 7 4659 0044

Table of Contents

Other manuals for Fronius CMT 4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius CMT 4000 Advanced and is the answer not in the manual?

Fronius CMT 4000 Advanced Specifications

General IconGeneral
BrandFronius
ModelCMT 4000 Advanced
CategoryAC Power Distribution
LanguageEnglish

Related product manuals