r | E34
r-calibration: Poor contact between the contact tube and the workpiece.
Clean the point of contact, tighten the contact tube, check the grounding
(earthing) connection
Cause:
Remedy:
tJO | xxx
At the same time, “E66” is displayed on the JobMaster
Note: xxx is a temperature value
Overheating in JobMaster welding torch
Allow the torch to cool, then acknowledge the error by pressing the Store
button
Cause:
Remedy:
tP1 | xxx
Note: xxx is a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down
Cause:
Remedy:
tP2 | xxx
Note: xxx is a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down
Cause:
Remedy:
tP3 | xxx
Note: xxx is a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down
Cause:
Remedy:
tP4 | xxx
Note: xxx is a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down
Cause:
Remedy:
tP5 | xxx
Note: xxx is a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down
Cause:
Remedy:
tP6 | xxx
Note: xxx is a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down
Cause:
Remedy:
tS1 | xxx
Note: xxx is a temperature value
Overtemperature in the secondary circuit of the power source
Allow power source to cool down
Cause:
Remedy: