131
g
Description Short interruption of power feeding into the grid due to over-
temperature.
The inverter returns to the startup phase.
Remedy Fault is rectified automatically
If this status code keeps recurring, contact your system installer
304
Over-temperature cooling element
Description Short interruption of power feeding into the grid due to over-
temperature.
The inverter returns to the startup phase.
Remedy Fault is rectified automatically
If this status code keeps recurring, contact your system installer
305
No power transfer to grid possible
Description Continual interruption of grid feed operation
Remedy Should the status code persist, you should contact your system
installer
'POWER LOW' (306)
Intermediate circuit voltage has dropped below permissible threshold value for feed in.
This error is shown on the inverter in plain text.
Description Short interruption of power feeding into the grid.
The inverter returns to the startup phase.
Remedy Fault is rectified automatically
If this status code keeps recurring, contact your system installer
'DC LOW' (307)
DC input voltage is too low for feed in.
This error is shown on the inverter in plain text.
Description Short interruption of power feeding into the grid.
The inverter returns to the startup phase.
Remedy Fault is rectified automatically
If this status code keeps recurring, contact your system installer
308
Intermediate circuit voltage too high.
Description Short interruption of power feeding into the grid.
The inverter returns to the startup phase.
Remedy Fault is rectified automatically
If this status code keeps recurring, contact your system installer