139
g
Description The Solar Net components required are in the inverter: Howev-
er, communication is still not currently possible.
Remedy Status code will disappear after changing the inverter address
505
EEPROM faulty
Description Data from the Setup menu are lost.
Remedy Remedied automatically
506
EEPROM faulty
Description Data from the ‘Total’ menu are lost.
Remedy Remedied automatically
507
EEPROM faulty
Description Data from the ‘Day’ / ‘Year’ menu are lost.
Remedy Remedied automatically
508
Inverter address incorrect
Description Address for data communication is no longer saved.
Remedy Set address again
509
24h no feed in
Description Example: solar modules covered with snow
Remedy Example: remove snow from solar modules
510
EEPROM faulty
Description SMS settings were restored to default.
Remedy If necessary, reconfigure SMS
511
EEPROM faulty
Description Sensor card settings were restored to default
Remedy If necessary, reconfigure measuring channels
512
Too many power stage sets in the system

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus 100 V-1 and is the answer not in the manual?

Fronius IG Plus 100 V-1 Specifications

General IconGeneral
BrandFronius
ModelIG Plus 100 V-1
CategoryInverter
LanguageEnglish

Related product manuals