51
g
1
10 mm
4
CAUTION! Danger of damaging the inverter by overload.
- Only connect a maximum of 20 A to an individual DC terminal.
- Connect the DC+ and DC- cables to the correct DC+ and DC- terminals on
the inverter.
5
SMON
SMOFF
2
1
3
6
Tightening torque of terminals:
1.2 - 1.5 Nm
IMPORTANT!
- Set the jumper from the 'SM
ON
' position to the 'SM
OFF
' position for correct measure-
ment results
- Check the polarity and voltage of the solar module strings: the voltage should be a
max. of 600 V, the difference between the individual solar module strings should be a
max. of 10 V.